How Do You Read a Pultruded FRP Grating Load Table?
Choosing pultruded FRP grating is not only about selecting the right panel size or thickness. The grating also has to perform across the required span while supporting the loads expected in the application.
That is where a pultruded FRP grating load table becomes important. Load tables provide information about deflection and load capacity at different spans, helping contractors, engineers, facility managers, and other buyers compare grating options for a project.
National Grating provides pultruded fiberglass grating in several bearing bar profiles and sizes for industrial, commercial, marine, transportation, water treatment, and other applications. Understanding the load table can help you narrow down the options before placing an order.
Key Takeaways
- Pultruded FRP grating load tables help compare grating styles based on span, load, and deflection.
- The bearing bars run in the span direction and are responsible for carrying the load.
- National Grating offers I-Shape, T-Shape, and High-Load bar profiles for different applications.
- Longer unsupported spans generally result in greater deflection under the same load.
- Concentrated and uniform loads affect grating differently, so the correct table needs to be used.
- Proper support and installation are important for achieving the intended performance of the grating.
Understanding a Pultruded FRP Grating Load Table
A pultruded FRP grating load table shows how a particular grating style performs at different spans and loads. National Grating’s brochure includes separate tables for concentrated line loads and uniform loads, with deflection values listed for multiple grating styles and span lengths.
Deflection refers to how much the grating bends under a specified load. The tables also provide maximum recommended loads and ultimate capacities for the listed configurations. These numbers make it possible to compare products rather than selecting grating based on thickness alone.
The distinction between recommended load and ultimate capacity is important. Ultimate capacity should not be treated as the normal working load for a project. The appropriate grating should be selected according to the project’s design requirements, applicable safety factors, support conditions, and expected loads.
Need the complete load tables and specifications? Download National Grating’s Pultruded FRP Grating Load Table Brochure to review concentrated load, uniform load, stair tread, fabrication, and product specification information.
Span Direction and Bearing Bars
The span direction matters because pultruded grating is designed differently from molded fiberglass grating. With pultruded FRP grating, the bearing bars carry the load and must run in the direction of the span.
National Grating explains that the length of a pultruded grating panel is the bearing bar direction. The width consists of the cross rods and is not intended to carry the primary load. This makes it important to know how the panel will sit on its supports before determining the required dimensions or ordering material.
A panel may physically fit an opening when turned in either direction, but that does not mean both orientations provide the same structural performance. The bearing bars need to span between the supports as intended.
Pultruded Grating Bearing Bar Profiles
National Grating’s pultruded grating is available with I-Shape, T-Shape, and High-Load bar profiles. Each category provides options for different applications and load requirements.
I-Shape bars provide a high strength-to-weight ratio and are available in several profiles. T-Shape bars provide greater surface area and are commonly used for pedestrian applications such as walkways, stairs, decks, pool areas, and similar surfaces. High-Load bars are intended for heavy-duty applications where greater load capacity may be required.
These profiles are available in different depths and open-area configurations. Rather than assuming one profile is appropriate for every project, the load requirements, span, traffic, environment, and support layout should all be considered.
If you are comparing pultruded fiberglass grating for an upcoming project, National Grating can help you review the available profiles and determine which options match your specifications.
How Span Affects FRP Grating Deflection
As the unsupported span increases, grating generally deflects more under the same load. This relationship can be seen throughout the concentrated and uniform load tables in National Grating’s brochure.
For that reason, the distance between supports is an important part of product selection. A grating configuration that performs well across a shorter span may not provide the same performance when the supports are farther apart.
The brochure includes data for spans ranging from 12 inches through 72 inches, depending on the grating style and load condition. Rather than selecting a panel first and adjusting the supports later, it is useful to consider the grating and support layout together.
Concentrated Loads vs. Uniform Loads
A concentrated load places force on a limited area or line of the grating, while a uniform load distributes force across a larger portion of the surface. Because those loads act differently, National Grating provides separate performance tables for each condition.
The concentrated line load table shows deflection under different loads at various spans. The uniform load table provides deflection information for distributed loads and lists maximum recommended loads and ultimate capacities in pounds per square foot.
Knowing which type of load best represents the application is necessary when reviewing the tables. A walkway supporting pedestrian traffic, for example, does not necessarily place the same type of demand on the grating as equipment or another concentrated load.
Proper Support for FRP Floor Grating
Even properly selected fiberglass grating depends on adequate support. National Grating recommends reading the applicable load tables to determine support spacing and making sure the floor grates receive.